Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Indian J Ophthalmol ; 2020 Apr; 68(4): 573-576
Article | IMSEAR | ID: sea-197897

ABSTRACT

Purpose: The aim of this study is to compare the outcome and complications in patients who underwent double-head pterygium excision with split conjunctival autograft with and without limbus to limbus orientation. Methods: In this retrospective, comparative study, 99 eyes with double-head pterygium which underwent split conjunctival autograft with limbus to limbus orientation (Group 1) and 93 eyes which underwent without limbus to limbus orientation (Group 2) during the period of 2011�16 were included in this study. The primary outcome compared was the recurrence rate. Other complications were included as secondary outcomes. Results: Mean age in group 1 and group 2 were 46.84 +/- 10.78 years and 54.38 +/- 11.44 years respectively. M:F was 36:63 in group 1 and 45:48 in group 2 with a mean follow up of 18.30 +/- 7.48 months in group 1 and 17.04 +/- 9.98 months in group 2. Recurrence was seen in 4 cases in each of the 2 groups with the mean time of recurrence being 7 +/- 2.34 months in group 1 and 6 +/- 2.01 months in group 2. Other complications included graft edema, SCH, graft retraction, granuloma, dellen and graft loss with only graft loss being statistically significant between 2 groups. Conclusion: This study provides data that recurrence rates are not different among patients who undergo split conjunctival graft with and without limbal orientation. The strict adherence to maintaining limbus to limbus orientation while managing double-headed pterygia may not be necessary in all cases, especially in those with large defects following excision.

2.
Indian J Ophthalmol ; 2019 Jul; 67(7): 1061-1065
Article | IMSEAR | ID: sea-197338

ABSTRACT

Purpose: To compare clinical outcomes following implantation of two types of posterior chamber phakic intraocular lenses: Visian™ Implantable Collamer Lens with Centraflow (ICL, V4C Staar Surgical, Nidau, Switzerland) and Implantable Phakic Contact Lens (IPCL, V1, Caregroup Sight Solution, India) for the correction of myopia and myopic astigmatism. Methods: This retrospective case series included eyes which underwent phakic intraocular lens implantation with a minimum follow-up period of 1 year. Visual outcomes including safety, efficacy, refractive predictability, and stability were compared at 1 week and at 1, 6, and 12 months' postoperative visit. Complications and adverse events were analyzed. Results: The study included 119 and 203 eyes in the IPCL and ICL groups, respectively. At 1-year postoperative visit, median corrected distance visual acuity was 0.10 (interquartile range [IQR] 0,0.10) and 0 (IQR 0,0) in the IPCL and ICL cohorts, respectively (P = 0.066). An uncorrected visual acuity of 20/32 or better was achieved in 86.5% and 88.67% of the eyes, respectively (P = 0.574). Ninety and 94% of the eyes achieved a postoperative manifest spherical equivalent within ± 0.5D (P = 0.169, ?2 test). Three eyes (2.52%) in the IPCL group versus one eye (0.49%) in the ICL group developed visually significant cataract requiring surgical intervention (P = 0.113). No vision-threatening complications were noted in either cohort. The mean follow-up period was 94.69 ± 32.45 and 102.67 ± 61.82 weeks, respectively. Conclusion: Both groups demonstrated similar efficacy and safety profile. The IPCL is an effective and economically viable option for the correction of myopia.

3.
Indian J Ophthalmol ; 2018 Nov; 66(11): 1558-1561
Article | IMSEAR | ID: sea-196990

ABSTRACT

Purpose: To compare the visual outcomes and higher order aberrations (HOAs) following wavefront optimized (WFO) laser in situ keratomileusis (LASIK) versus topography-guided customized ablation (TCAT) LASIK for myopia and myopic astigmatism. Methods: Patients who underwent femtosecond-assisted LASIK for myopic correction between August 2016 and October 2017 were included in this interventional prospective case series. The following parameters were evaluated preoperatively and at 3 months' postoperative visit: uncorrected distance vision acuity (UDVA) and corrected distance vision acuity (CDVA), manifest refraction, and HOAs. Results: Two hundred eyes of 100 patients were included in the study. At 3 months' postoperative visit, 92% and 90% eyes in the TCAT and WFO groups, respectively, demonstrated a UDVA of 20/20 or better (P = 0.90). A residual manifest spherical equivalent within 0.5 D was achieved in 100% and 95% of the eyes in the TCAT and WFO groups, respectively (P = 0.10). No significant difference was observed in the HOAs induced in both the groups, with slightly lower induction of trefoil and horizontal coma in the TCAT group. Conclusion: Both groups demonstrated similar refractive efficacy and predictability, with greater gain of CDVA following TCAT ablation. HOAs induced were not significantly different between the two groups. Further studies are needed to validate the superiority of one procedure over the other.

4.
Indian J Ophthalmol ; 2018 Mar; 66(3): 407-410
Article | IMSEAR | ID: sea-196631

ABSTRACT

Purpose: The aim of this study was to analyze the objective and subjective visual outcomes of patients bilaterally implanted with the extended range of vision intraocular lens (EROV IOL), the Tecnis Symfony. Methods: This was a prospective interventional case series conducted at a tertiary eye care hospital in South India. The study included patients with bilateral implantation of EROV IOLs. The uncorrected and corrected visual acuity for distance, intermediate, and near vision was recorded at 6 weeks and 6 months' postoperative visit. A subjective questionnaire was administered to assess spectacle independence, photic phenomenon, and overall satisfaction. All data were recorded using Microsoft Excel worksheet. The analyses were performed using SPSS for windows software. Results: Our study included fifty patients with bilateral implantation of EROV IOLs. The mean age was 59.84 ± 11.68 years. The mean uncorrected binocular distance, intermediate, and near visual acuity (in standard decimal equivalent) was 0.89,0.99 and 0.99 respectively, at 6 months' postoperative visit. Ninety-six percent of the patients did not require spectacles for distance and 98% of the patients were free from spectacles for intermediate and near vision. 94% of our patients perceived no or minimal photic phenomena such as glare and halos. The mean subjective patient satisfaction score (out of 10) for distance, intermediate, and near was 9, 10, and 9, respectively. Conclusion: The EROV IOLs demonstrated high levels of spectacle independence for distance, intermediate, and near vision. The incidence of photic phenomena observed was minimal with a high level of patient satisfaction.

SELECTION OF CITATIONS
SEARCH DETAIL